763 research outputs found

    Nonlinear Optical studies of the Transient Coherence in the Quantum Hall System

    Full text link
    We review recent investigations of the femtosecond non-linear optical response of the two-dimensional electron gas (2DEG) in a strong magnetic field. We probe the Quantum Hall (QH) regime for filling factors ν1\nu \sim 1. Our focus is on the transient coherence induced via optical excitation and on its time evolution during early femtosecond timescales. We simultaneously study the interband and intraband coherence in this system by using a nonlinear spectroscopic technique, transient three-pulse four wave mixing optical spectroscopy, and a many-body theory. We observe striking differences in the temporal and spectral profile of the nonlinear optical signal between a modulation doped quantum well system (with the 2DEG) and a similar undoped quantum well (without a 2DEG). We attribute these qualitative differences to Coulomb correlations between the photoexcited electron-hole pairs and the 2DEG. We show, in particular, that intraband many-particle coherences assisted by the inter-Landau-level magnetoplasmon excitations of the 2DEG dominate the femtosecond nonlinear optical responce. The most striking effect of these exciton-magnetoplasmon coherences is a large off-resonant four-wave-mixing signal in the case of very low photoexcited carrier densities, not observed in the undoped system, with strong temporal oscillations and unusually symmetric temporal profile.Comment: 22 pages, 9 figures; review article to be published in Solid State Communication

    Impact of the implantable cardioverter-defibrillator on rehospitalizations

    Get PDF
    Patients who survive out-of-hospital ventricular tachycardia or ventricular fibrillation are at risk of sudden cardiac death and often return to hospital after initial discharge. The frequency and duration of readmittance to hospital are not well known. Thus, the purpose of this study was to evaluate the impact of the implantable cardioverter defibrillator on frequency and duration of hospitalizations. Methods Between 1989 and 1993, 38 consecutive patients who had drug-refractory ventricular tachyarrhythmias were selected for the study. A total of 38 patients were implanted with the implantable cardioverter-defibrillator in accordance with the guidelines of the European Society of Cardiology. This analysis includes 35 of the 38 patients (92%). All hospitalizations which occurred one year before and one year after were studied. Clinical information for all patients was obtained by consulting medical records and by interviewing personal general practitioners. Results The annual number of hospitalizations before and after implantation of the implantable cardioverter defibrillator was, respectively, 3·28 ± 2 hospitalizations/patient/year and 0·88 ± 1·23 hospitalizations/patient/year (P<0·05). Before implantation of the implantable cardioverter-defibrillator, patients were hospitalized a mean of 32·94 plusmn; 24·18 days/patient/year and after, 9·31 ± 32·14 days/patient/year (P<0·05). The number of hospitalizations for cardiac reasons decreased by 90%. Before implantation, the most frequent cause was ventricular tachyarrhythmia (47 hospitalizations for ventricular tachycardia and eight for ventricular fibrillation), while after implantation, it was as a result of the shock from the implantable cardioverter defibrillator (II hospitalizations). The number of hospitalizations for non-cardiac reasons were similar in the two time periods. Of the 35 patients, 26 (74%) had at least one appropriate successful ventricular tachycardia interrupted by the implantable cardioverter-defibrillator, while 17 patients (49%) had their ventricular fibrillation terminated. There is a significant difference in the rate of hospitalizations to intensive care units (ICU) between the two periods. Before implantation, 30% of hospital days were spent in the ICU, with 3% after. Conclusions This study documents that the implantable cardioverter-defibrillator not only reduces the frequency and duration of hospital stays, but reduces admissions to the more expensive units in hospital. Taking into account the reduction in hospitalizations, the payback period for the implantation of an implantable cardioverter-defibrillator is 19 months. (Eur Heart J 1996; 17: 1565-1571

    Is there an isolated arrhythmogenic right atrial myocarditis?

    Get PDF
    Two cases with drug refractory ectopic atrial tachycardia are described. A map-guided partial resection of the right atrium (RA) was done after preoperative endocardial catheter mapping hadshown well-defined areas of fractionated RA potentials. Intraoperatively, there were no aneurysmal formations present as described by other authors. Histopathologic examination of the resected tissue showed atrial myocarditis in both patients. Postoperative right ventricular myocardial biopsies revealed no inflammatory tissue. A minor elevation of antibodies against echoviruses was found in one case. Postoperative electrophysiologic studies were negative. We conclude: focal RA myocarditis without concomitant ventricular myocarditis may represent one cause of drug-resistant ectopic atrial tachycardia. Map-guided surgical intervention may cure the diseas

    Predictive models of syncope causes in an outpatient clinic

    Get PDF
    The investigation of unexplained syncope remains a challenging clinical problem. In the present study we sought to evaluate the diagnostic value of a standardized work-up focusing on non invasive tests in patients with unexplained syncope referred to a syncope clinic, and whether certain combinations of clinical parameters are characteristic of rhythmic and reflex causes of syncope. METHODS AND RESULTS: 317 consecutive patients underwent a standardized work-up including a 12-lead ECG, physical examination, detailed history with screening for syncope-related symptoms using a structured questionnaire followed by carotid sinus massage (CSM), and head-up tilt test. Invasive testings including an electrophysiological study and implantation of a loop recorder were only performed in those with structural heart disease or traumatic syncope. Our work-up identified an etiology in 81% of the patients. Importantly, three quarters of the causes were established non invasively combining head-up tilt test, CSM and hyperventilation testing. Invasive tests yielded an additional 7% of diagnoses. Logistic analysis identified age and number of significant prodromes as the only predictive factors of rhythmic syncope. The same two factors, in addition to the duration of the ECG P-wave, were also predictive of vasovagal and psychogenic syncope. These factors, optimally combined in predictive models, showed a high negative and a modest positive predictive value. CONCLUSION: A standardized work-up focusing on non invasive tests allows to establish more than three quarters of syncope causes. Predictive models based on simple clinical parameters may help to distinguish between rhythmic and other causes of syncop

    Intermittent atrial tachycardia facilitates atrial fibrillation by a shortening of activation recovery interval

    Get PDF
    Introduction: We recently observed in a chronic ovine model that a shortening of action potential duration (APD) as assessed by the activation recovery interval (ARI) may be a mechanism whereby pacing-induced atrial tachycardia (PIAT) facilitates atrial fibrillation (AF), mediated by a return to 1:1 atrial capture after the effective refractory period has been reached. The aim of the present study is to evaluate the effect of long term intermittent burst pacing on ARI before induction of AF.Methods: We specifically developed a chronic ovine model of PIAT using two pacemakers (PM) each with a right atrial (RA) lead separated by ∼2cm. The 1st PM (Vitatron T70) was used to record a broadband unipolar RA EGM (800 Hz, 0.4 Hz high pass filter). The 2nd was used to deliver PIAT during electrophysiological protocols at decremental pacing CL (400 beats, from 400 to 110ms) and long term intermittent RA burst pacing to promote electrical remodeling (5s of burst followed by 2s of sinus rhythm) until onset of sustained AF. ARI was defined as the time difference between the peak of the atrial repolarization wave and the first atrial depolarization. The mean ARIs of paired sequences (before and after remodeling), each consisting of 20 beats were compared.Results: As shown in the figure, ARIs (n=4 sheep, 46 recordings) decreased post remodeling compared to baseline (86±19 vs 103±12 ms, p&lt;0.05). There was no difference in atrial structure as assessed by light microscopy between control and remodeled sheep.Conclusions: Using standard pacemaker technology, atrial ARIs as a surrogate of APDs were successfully measured in vivo during the electrical remodeling process leading to AF. The facilitation of AF by PIAT mimicking salvos from pulmonary veins is heralded by a significant shortening of ARI

    Is there an isolated arrhythmogenic right atrial myocarditis?

    Get PDF
    Two cases with drug refractory ectopic atrial tachycardia are described. A map-guided partial resection of the right atrium (RA) was done after preoperative endocardial catheter mapping had shown well-defined areas of fractionated RA potentials. Intraoperatively, there were no aneurysmal formations present as described by other authors. Histopathologic examination of the resected tissue showed atrial myocarditis in both patients. Postoperative right ventricular myocardial biopsies revealed no inflammatory tissue. A minor elevation of antibodies against echoviruses was found in one case. Postoperative electrophysiologic studies were negative. We conclude: focal RA myocarditis without concomitant ventricular myocarditis may represent one cause of drug-resistant ectopic atrial tachycardia. Map-guided surgical intervention may cure the disease

    Impact of the implantable cardioverter-defibrillator on rehospitalizations

    Get PDF
    Patients who survive out-of-hospital ventricular tachycardia or ventricular fibrillation are at risk of sudden cardiac death and often return to hospital after initial discharge. The frequency and duration of readmittance to hospital are not well known. Thus, the purpose of this study was to evaluate the impact of the implantable cardioverter defibrillator on frequency and duration of hospitalizations. METHODS: Between 1989 and 1993, 38 consecutive patients who had drug-refractory ventricular tachyarrhythmias were selected for the study. A total of 38 patients were implanted with the implantable cardioverter-defibrillator in accordance with the guidelines of the European Society of Cardiology. This analysis includes 35 of the 38 patients (92%). All hospitalizations which occurred one year before and one year after were studied. Clinical information for all patients was obtained by consulting medical records and by interviewing personal general practitioners. RESULTS: The annual number of hospitalizations before and after implantation of the implantable cardioverter-defibrillator was, respectively, 3.28 +/- 2.38 hospitalizations/ patient/year and 0.88 +/- 1.23 hospitalizations/patient/year (P &lt; 0.05). Before implantation of the implantable cardioverter-defibrillator, patients were hospitalized a mean of 32.94 +/- 24.18 days/patient/year and after, 9.31 +/- 32.14 days/patient/year (P &lt; 0.05). The number of hospitalizations for cardiac reasons decreased by 90%. Before implantation, the most frequent cause was ventricular tachyarrhythmia (47 hospitalizations for ventricular tachycardia and eight for ventricular fibrillation), while after implantation, it was as a result of the shock from the implantable cardioverter-defibrillator (11 hospitalizations). The number of hospitalizations for non-cardiac reasons were similar in the two time periods. Of the 35 patients, 26 (74%) had at least one appropriate successful ventricular tachycardia interrupted by the implantable cardioverter-defibrillator, while 17 patients (49%) had their ventricular fibrillation terminated. There is a significant difference in the rate of hospitalizations to intensive care units (ICU) between the two periods. Before implantation, 30% of hospital days were spent in the ICU, with 3% after. CONCLUSIONS: This study documents that the implantable cardioverter-defibrillator not only reduces the frequency and duration of hospital stays, but reduces admissions to the more expensive units in hospital. Taking into account the reduction in hospitalizations, the payback period for the implantation of an implantable cardioverter-defibrillator is 19 months

    Fermi-edge singularities in linear and non-linear ultrafast spectroscopy

    Get PDF
    We discuss Fermi-edge singularity effects on the linear and nonlinear transient response of an electron gas in a doped semiconductor. We use a bosonization scheme to describe the low energy excitations, which allows to compute the time and temperature dependence of the response functions. Coherent control of the energy absorption at resonance is analyzed in the linear regime. It is shown that a phase-shift appears in the coherent control oscillations, which is not present in the excitonic case. The nonlinear response is calculated analytically and used to predict that four wave-mixing experiments would present a Fermi-edge singularity when the exciting energy is varied. A new dephasing mechanism is predicted in doped samples that depends linearly on temperature and is produced by the low-energy bosonic excitations in the conduction band.Comment: long version; 9 pages, 4 figure

    Ultrafast Nonlinear Optical Response of Strongly Correlated Systems: Dynamics in the Quantum Hall Effect Regime

    Full text link
    We present a theoretical formulation of the coherent ultrafast nonlinear optical response of a strongly correlated system and discuss an example where the Coulomb correlations dominate. We separate out the correlated contributions to the third-order nonlinear polarization, and identify non-Markovian dephasing effects coming from the non-instantaneous interactions and propagation in time of the collective excitations of the many-body system. We discuss the signatures, in the time and frequency dependence of the four-wave-mixing (FWM) spectrum, of the inter-Landau level magnetoplasmon (MP) excitations of the two-dimensional electron gas (2DEG) in a perpendicular magnetic field. We predict a resonant enhancement of the lowest Landau level (LL) FWM signal, a strong non-Markovian dephasing of the next LL magnetoexciton (X), a symmetric FWM temporal profile, and strong oscillations as function of time delay, of quantum kinetic origin. We show that the correlation effects can be controlled experimentally by tuning the central frequency of the optical excitation between the two lowest LLs.Comment: 21 pages, 10 figure
    corecore